Asko WMC Service Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
62
SERVICE
CROSS MEMBER
Changing the input terminal block
1. Remove the top cover by first removing the 3
screws at the rear edge and then lifting the cover
off.
2. Remove the earthing screw.
3. Disconnect all the wiring.
4. Press the latches in with a screwdriver and pull
out the input terminal block.
NOTE
Make sure that the wires are connected correctly
when changing the input terminal block and the
connection cables.
5. Install the new input terminal block, the lat-
ches must clip on to the edge of the plate.
6. Install the wiring in accordance with the elec-
trical schematic diagram.
7. Secure the earthing screw.
IMPORTANT
Don't forget to put the earthing screw back.
8. Fit the top cover.
4
2
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 83 84

Comments to this Manuals