23
CONSUMPTION VALUES
Program Material/Temperature Load size
Water consumption
(approx. litres)
Total
(hot+cold water)
Energy
approx. kWh
(cold /mixed inlet)
Time
approx. min
(cold /mixed inlet)
P1 Cotton, linen 90°C1/1 (5,0 kg)
80
(3+77)
2,0/1,9 82/77
P2 Cotton, linen 60°C1/1 (5,0 kg)
80
(3+77)
1,6/1,5 57/52
P3 Cotton, linen 90°C1/1 (5,0 kg)
72
(6+66)
1,6/1,5 70/65
P4 Cotton, linen 60°C1/1 (5,0 kg)
65
(6+59)
1,1/0,82 57/52
P5 Cotton, linen 40°C1/1 (5,0 kg)
65
(6+65)
0,40/0,40 40/40
P6 Synthetic 40°C1/2 (2,5 kg)
54
(0+54)
0,35/0,35 25/25
P7 Wool /handwash 30°C1/3 (1,7 kg)
76
(0+76)
0,25/0,25 25/25
P8 One rinse, Long spin 1/1 (5,0 kg)
18
(0+18)
0,05/0,05 11/11
The following conditions apply for the consump-
tion values stated below:
Incoming water temperature
cold:15°C.
hot: 60°C.
Heater: 3500W.
Option: cold inlet
PROGRAMME VERSION MOP
85/80
59/54
73/68
59/54