Connecting a Four-wire Power Cord
Connecting a Three-wire Power Cord
ELECTRICAL CONNECTIONSELECTRICAL CONNECTIONS
The power supply cord must be grounded. If the
machine is to be used in a wet area, the supply must
be protected by a residual current device.
CAUTION:
The receptacle on the rear of the machine is designed
to accommodate ASKO washers ONLY (rated 208–
240 V.) To use this receptacle, you must use the ready-
fitted plug supplied with the washing machine or an
equivalent. The supply connection must be 208–240 V,
20 A.
ASKO washers rated 208–240 V have two internal
fuses of 15 A each.
Remove cover to
access terminal box.
(Requires a 20-Torx
screwdriver.)
WARNING! Before starting this procedure, be sure
the power is turned off at the breaker/fuse box.
WARNING! Before starting this procedure, be sure
the power is turned off at the breaker/fuse box.
1. Turn the power off at the breaker/fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the terminal
block opening.
4. Loosen or remove center terminal block screw.
5. Connect neutral wire
(white ) of power
supply cord to the
center, silver-colored
terminal screw.
Tighten screw.
6. Connect the other
wires to outer screws.
7. Tighten the strain
relief screws.
8. Replace terminal box
cover on back of dryer.
9. Plug dryer into wall
receptacle.
10. Turn power on at
breaker/fuse box.
Power Supply Cord
You will need a three-wire power supply cord with three
No. 10 copper wires and a matching three-wire
receptacle of NEMA Type 10-30R, as illustrated below:
1. Turn the power off at the breaker/fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the terminal
block opening.
4. Remove center terminal block screw.
5. Remove ground wire
(green with yellow stripes)
from external ground
connector screw. Fasten
under center, silver-
colored terminal block
screw.
6. Connect ground wire
(green) of cord to external
ground conductor screw.
7. Connect neutral wire (white)
of cord under center screw
of terminal block.
8. Connect the other wires
to outer screws.
9. Tighten the strain relief screws.
10. Replace terminal box cover on back of dryer.
11. Plug dryer into wall receptacle.
12. Turn power on at breaker/fuse box.
Spade terminals
with upturned
ends
FOUR-WIRE CORD
Neutral
Ground
prong
Ring
terminals
Neutral
(white)
Ground
(green)
3/4” UL-listed
strain relief
Power Supply Cord
You will need a four-wire power supply cord with four
No. 10 copper wires and a matching four-wire
receptacle of NEMA Type 14-30R, as illustrated below.
The fourth wire must be identified with a green cover
and the neutral conductor by a white cover.
NOTE: In Canada, the dryer is delivered ready-fitted with
a four-prong plug intended for connection to a single-
phase supply.
Connection to a permanently wired supply point must
be made only by a qualified electrician.
As supplied: Single-phase, 230 V, 60 Hz,
2500 Watt heater rating
30 A fuse required
THREE-WIRE CORD
Spade terminals
with upturned
ends
Ring
terminals
This blade connects
to this conductor.
Neutral
3/4” UL-listed
strain relief
Neutral
(white)
4
5
7
6
8
5
7
6
9
4
Page view 11