The machine will not start
Check
that the door is properly closed.
that the main power switch is on.
that the Delayed Start option has not been se-
lected. To cancel Delayed Start, press the Stop
button for 3 seconds.
that any plug is connected.
that the fuses (circuit breakers) in your house
are intact. Flip the dryer breaker off and then
back on to make sure. You can not always tell
from the outside if the circuit breaker has
tripped.
that the overheating cut-off has not been trig-
gered (see below).
Overheating cut-off
The overheating cut-off shuts off the tumble dryer
if the temperature is too high, caused by lint
clogging the lint filter, for instance.
Clean the filter.
Check that the condenser is clean. Clean it if
necessary. See the "Care and cleaning"
chapter.
The overheating cut-off will reset automatically
once the machine has cooled down.
Drying takes too long
Check that the lint filter and the condenser are
not blocked. See the "Care and maintenance"
chapter.
Prolonged drying times may also be due to the
tumble dryer being located in a confined space
or room that is too small, causing the air to
become too hot.
Make sure that the tumble dryer has access
to more cold air, by opening doors and/or win-
dows, for example.
The laundry does not dry, or is too
dry
The door has been opened while the program
is running, which disrupts the moisture monitor-
ing function.
Error messages
If Overflow is shown in the display, the con-
denser drain hose could be blocked. Remove
the hose from the drain and check for obstruc-
tions. The hose should be inserted no more
than 5 or 6 inches into the wall drain.
If "Max Program Time" appears on the display,
the maximum program time has been reached.
Read "Drying takes too long" in the "Trou-
bleshooting" chapter to find out what to do.
If "Clean lint filter" appears on the display,
clean the lint filter.
If "Clean condenser" appears on the display.
See the "Cleaning the condenser" section of
the "Care and cleaning" chapter for remedy
Press the Stop button to close error messages.