Electrical Connections
WARNING!
Read the Electrical requirements and grounding
instructions before connecting the tumble dryer.
Electric models of the dryer are manufactured for
a 3-wire connection system. The dryer frame is
grounded by a link to the neutral conductor on the
dryer terminal block. If local codes do not permit
grounding through the neutral, the grounding link
from the terminal block must be removed and a
separate ground wire must be used.
Only a 4-conductor cord shall be used when the
appliance is installed in a location where
grounding through the neutral conductor is
prohibited. Grounding through the neutral
conductor is prohibited for new branch-circuit
installations, mobile homes, recreational vehicles,
and areas where local codes prohibit grounding
through the neutral conductors. The grounding
link on the dryer must be removed for all 4-wire
installations.
These Electrical Connection instructions provide
for installing the dryer in the following situations:
3-wire connection where local codes permit
grounding through the neutral. 3-wire connection
plus separate grounding connector where local
codes do not permit grounding through the
neutral.
4-wire connection.
Each of the above connections can be made with
an approved power supply cord or by direct wiring.
Each connection instruction identifies the
appropriate Power Supply Cord and covers
requirements for direct wiring.
NOTE!
In Canada, the dryer is delivered ready-fitted
with a four-prong plug intended for connection
to a single-phase supply.
Connecting a 3-wire Power Cord
WARNING!
Before starting this procedure, be sure the power
is turned off at the breaker/fuse box.
Power Supply Cord
You will need a 3-wire power supply cord with
three No. 10 copper wires and a matching 3-wire
receptacle of NEMA Type 10-30R, as illustrated
below:
To connect a 3-wire power cord to the dryer,
follow the steps below.
NOTE!
The numbers in the illustration below correlate
to the step numbers.
1. Turn the power off at the breaker or fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the
terminal block opening.
4. Loosen or remove center terminal block screw.