COMPONENT INFORMATION
Flowmeter
The ow meter is tted in the air gap. The
ow meter is used to control the water intake
so that the right volume is taken in regard-
less of the water pressure. It is even possible
to program the machine for time-controlled
water intake.
The ow meter comprises an impeller with two
magnets that is driven by the water ow. On the
outside, on the ow meter housing, is a sensor,
a reed switch, which closes each time the mag-
nets pass. The number of pulses from the sensor
is proportional to the volume of the owing
water. A minimum water ow of 2 litres/minute
is required for the ow meter to operate. If
the necessary level is not reached within one
minute, the program stops.
Output signal: 220 pulses per litre.
Circulation pump
The circulation pump comprises an asynchro-
nous motor, with a pump house capacitor.
4.2 Components and function description
Here we present the functions and specica-
tions of the various electrical components.
Some components are only found in high-end
machines or in particular markets.
Inlet valve
Both single and safety inlet valves are used.
The valve contains a lter to stop particles then
a ow limiter to limit the ow to a maximum of
4 l/min. The valve opens when the water pres-
sure exceeds 0.3 bar and provides full ow at
about 2 bar.
Safety valve
The safety valve has two independent valve
seats, each controlled by a separate elec-
tromagnet. The valve seats are connected
in series. This doubles the safety factor. The
electromagnets are also connected in series
(electrically), which means each magnet’s
rated voltage is half the mains voltage (e.g., a
230 V valve = 2 x 115 V coils)
Single valve
The single valve comprises an electromagnet
and a valve seat.
Article no. Position Component Measurement
value
8078302*
8078302*
Softener salt water
valve 120 V
0.65 kohm
Softener mixer valve
120 V
0.65 kohm
8073830 Halogen bulb 5 W/12 V
<10 kohm
8052778 Vax motor
1.1 kohm
8073850 Fan motor 230 V
0,44 kohm
8073848 Fan motor 120 V
0.18 kohm
* The number is for a complete water softener; replacement salt and mixer valves are not
available separately.